Latching current for an SCR is 100 mA, DC source of 200 V is also connected from the SCR to the L load. Compute the minimum width of the gate pulse required to turn on the device. Take L = 0.2 H. - Study24x7
Social learning Network
study24x7

Default error msg

Login

New to Study24x7 ? Join Now
Already have an account? Login
18 Apr 2019 12:02 PM study24x7 study24x7

Latching current for an SCR is 100 mA, DC source of 200 V is also connected from the SCR to the L load. Compute the minimum width of the gate pulse required to turn on the device. Take L = 0.2 H.
See more

A

50 μsec

B

100 μsec

C

150 μsec

D

200 μsec

study24x7
Write a comment
  • geet sharma
  •  For L load, E = L di/dt
    I = E/L t
    Therefore, 0.100 = 200t/0.2
    T = 100 μsec.

    See more

    Related Questions
    500+   more Questions to answer
    Most Related Articles