 SCRs with a rating of 1000 V & 200 A are available to be used in a string to handle 6 KV & 1 KV. Calculate the number of series & parallel units required in case the de-rating factor is 0.1. (Round off the fraction to the greatest & nearest integer)

See more

A

Series = 7, Parallel = 6

B

Series = 6, Parallel = 7

C

Series = 6, Parallel = 6

D

Series = 7, Parallel = 7

study24x7
Write a comment
  • geet sharma
  • DRF = 1-S.E
    Therefore
    0.1 = (1-6000/1000Ns) = (1-1000/200Np)
    Ns = 6.6 = 7(say)
    Np = 5.5 = 6(say)